User Tools

Site Tools


Joomla says you aren't logged in
model_config:syma_x5sc_explorer_2:symax5scexplorer2
name=Syma X5SC 2
mixermode=Advanced
type=multi
[radio]
protocol=SymaX
num_channels=9
fixed_id=146812
tx_power=100mW
 
[protocol_opts]
SymaX5C=Off
 
[channel1]
subtrim=65
template=complex
[mixer]
src=AIL
dest=Ch1
scalar=60
curvetype=expo
points=50,50
[mixer]
src=AIL
dest=Ch1
switch=FMODE1
scalar=80
curvetype=expo
points=40,40
[mixer]
src=AIL
dest=Ch1
switch=FMODE2
usetrim=0
curvetype=expo
points=40,40
 
[channel2]
subtrim=50
template=complex
[mixer]
src=ELE
dest=Ch2
scalar=60
curvetype=expo
points=50,50
[mixer]
src=ELE
dest=Ch2
switch=FMODE1
scalar=80
curvetype=expo
points=40,40
[mixer]
src=ELE
dest=Ch2
switch=FMODE2
usetrim=0
curvetype=expo
points=40,40
 
[channel3]
template=complex
[mixer]
src=THR
dest=Ch3
usetrim=0
curvetype=expo
points=0,0
[mixer]
src=THR
dest=Ch3
switch=RUD DR1
scalar=-100
usetrim=0
curvetype=fixed
 
[channel4]
template=complex
[mixer]
src=RUD
dest=Ch4
scalar=75
usetrim=0
curvetype=expo
points=50,50
[mixer]
src=RUD
dest=Ch4
switch=FMODE1
curvetype=expo
points=40,40
[mixer]
src=RUD
dest=Ch4
switch=FMODE2
usetrim=0
curvetype=expo
points=40,40
 
[channel6]
template=simple
[mixer]
src=GEAR1
dest=Ch6
curvetype=expo
points=0,0
 
[channel7]
template=simple
[mixer]
src=Virt1
dest=Ch7
curvetype=expo
points=0,0
 
[channel8]
template=simple
[mixer]
src=Virt2
dest=Ch8
curvetype=expo
points=0,0
 
[channel9]
template=simple
[mixer]
src=AIL DR1
dest=Ch9
curvetype=min/max
points=0
 
[trim2]
src=RIGHT_V
pos=TRIMRV+
neg=TRIMRV-
[trim3]
src=LEFT_H
pos=TRIMLH+
neg=TRIMLH-
[trim4]
src=RIGHT_H
pos=TRIMRH+
neg=TRIMRH-
[trim5]
src=Virt1
pos=TRIMLV+
step=193
value=-100,0,0
[trim6]
src=Virt2
pos=TRIMLV-
step=193
value=-100,0,0
[timer1]
type=countdown
src=Ch3
time=240
[timer2]
src=MIX1
resetsrc=MIX2
[datalog]
switch=None
rate=1 sec
[safety]
Auto=min
[gui-128x64]
V-trim=55,10,1
H-trim=1,59,3
V-trim=69,10,2
H-trim=78,59,4
Big-box=2,12,Ch3
Small-box=2,28,Timer1
Small-box=2,38,Timer2
Small-box=2,48,Timer3
Bargraph=79,30,Ch1
Bargraph=85,30,Ch2
Bargraph=91,30,Ch3
Bargraph=97,30,Ch4
Bargraph=103,30,Ch5
Bargraph=109,30,Ch6
Bargraph=115,30,Ch7
Bargraph=121,30,Ch8
Toggle=75,13,1,64,128,FMODE
Toggle=84,13,2,65,129,MIX
Toggle=93,13,0,5,0,ELE DR
Toggle=102,13,0,4,0,AIL DR
Toggle=111,13,0,8,0,GEAR
Toggle=120,13,0,9,0,RUD DR
Battery=102,1
TxPower=75,1
quickpage1=Telemetry monitor
quickpage2=Channel monitor
quickpage3=Mixer
model_config/syma_x5sc_explorer_2/symax5scexplorer2.txt (48840 views) · Last modified: 2016/01/20 23:12 by Fer